UNO Control System

Product Code: UNI-SIX-004

£163.20 (Ex. VAT) £195.84 (Inc. VAT)

A single switch solution that has a momentary cyclic option and also has dual colour (red/blue) LED illumination that changes colour with each press to display selected 'mode of operation' or to indicate an 'off' status.

Supplied with a pre-programmed MCS-6E Universal Mini Controller and single cyclic switch.

Specification Dimensions Installation Guide Input/Output Functions

Controller (MCS-6E) Features and Functions:
• Pre-programmed to switch on two sets of outputs depending how many times the single push button is pressed
• 6 x 10Amp solid state relay outputs
• Collective total current rating is 24 Amp
• Each output can be current protected set at 5 or 10 Amps - no external fuses required
• Side light input for illumination control - positive
• Input Ignition input for wake-up control - positive
• Input Low battery 'auto shut down' feature sets in when voltage level falls below 11.5 volts for more than 30 seconds
• Automatic 'sleep mode' sets in after periods of inactivity or low voltage
• 12 and 24 volt operation

Single Cyclic Switch Features and Functions:
• Momentary 3-way cyclic switch with dual colour (blue and red) LED illumination that changes colour with each
press to display the selected mode of operation or is unlit when off
• 22mm front bezel micro switch
• Brushed steel anti-vandal switch
• Dual colour LED - blue/red
• Ingress protected to IP65

• 3 year manufacturers warranty

MCS-6E Unit Dimensions

INPUT RELATIONSHIP WITH OUTPUTS

INPUT
SWITCH
OPERATES
IP1
Not used
No action
IP2
Not used
No action
IP3
Not used
No action
IP4
Not used
No action
IP5
Not used
No Action
IP6
1st Press
2nd Press
3rd Press
Off
OP1 & OP4
OP2 & OP3

Note: This device is specifically pre-programmed to operate as described above.

OUTPUT FUNCTIONS

INPUT
FUNCTION
EXAMPLE BLUE LIGHT USE
EXAMPLE AMBER LIGHT USE
OP1
1st Group of Devices
999 Group
Towing Group
OP2
1st and 2nd Group of Devices
At Scene Group
Roadside Working Group
OP3
2nd Group of Devices
At Scene Group
Roadside Working Group
OP4
1st Group of Devices
999 Group
Towing Group
OP5
Blue LED in Switch
Not available to use
Not available to use
OP6
Red LED in Switch
Not available to use
Not available to use

Note: Each output can drive any appropriate device so long as each is rated under 10 Amp with a collective total of 24 Amp.